TenderDekho Logo
Active GEM

Contract Bidding Open For Ultrasound Machine (V2) in KAMRUP, ASSAM

Bid Publish Date

01-Sep-2026, 1:26 pm

Bid End Date

14-Sep-2026, 3:00 pm

EMD

₹36,000

Location

KAMRUP , ASSAM

Progress

Issue01-Sep-2026, 1:26 pm
AwardPending

All India Institute Of Medical Sciences (aiims) has released a public tender for Ultrasound Machine (V2) (Q2) in KAMRUP, ASSAM. Quantity: 1. Submission Deadline: 14-09-2026 15: 00: 00. Download documents and apply online.

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

Yes

MII Preference Band

L1+20%

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

9

OEM Avg. Turnover

72

Past Performance

10 %

Warranty Period

2 years

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Ultrasound Machine (V2) (Q2)

Advisory Bank

ICICI

ePBG Percentage

5%

ePBG Duration (Months)

26

Delivery Details

Max Delivery Days

45

Delivery Locations

1

Delivery Cities

Kamrup

Delivery Pincodes

781101

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Sumanjit Swadhin Boro781101,ChangsariKamrupAssam781101145-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9803782.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Categories 3

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERAL Product Description Ultrasound Machine
Types of Probes & Features Applications Abdomen, Abdominal vascular, Urology, OB/GYN, Neonatal brain, Small parts (breast, thyroid, scrotal, prostate, musculoskeletal)
Types of Probes & Features Convex Probe 2.5 to 5 MHz (±2)
Types of Probes & Features Microconvex probe Not Provided
Types of Probes & Features Linear array probe Not provided
Types of Probes & Features TVS Probe 4 to 9 MHz (±2)
Types of Probes & Features Cardiac Probe Not Provided
Types of Probes & Features Hockey Stick Probe Not Provided
Types of Probes & Features Volume Convex Probe Not Provided
Types of Probes & Features Volume Linear Probe Not Provided
Types of Probes & Features Volume TVS Probe Not Provided
Types of Probes & Features Endorectal Probe Not Provided
Types of Probes & Features E-Breast Elastography technique No
Types of Probes & Features E-Thyroid Elastography technique No
Types of Probes & Features Liver Elastography technique No
Types of Probes & Features Gel Warmer No
Types of Probes & Features Dedicated 3-D/4-D No
Scan Modes B-mode Yes
Scan Modes M-mode Yes
Scan Modes Contrast harmonic imaging with angio mode Yes
Scan Modes Tissue harmonic imaging mode Yes
Scan Modes Provision of Harmonic imaging in Linear Probes Yes
Scan Modes Color Doppler imaging (CDI) Yes
Scan Modes Color Doppler 3-D/4-D option No
Scan Modes Power Doppler imaging (PDI) Yes
Scan Modes Power Doppler 3-D/4-D option No
Scan Modes Continuous wave No
Scan Modes Pulsed wave Yes
Scan Modes Duplex mode Yes
Scan Modes Triplex mode Yes
Scan Modes Tissue Doppler imaging No
Scan Modes Contrast-enhanced ultrasound (CEUS) option No
Scan Modes Tissue synchronization, tissue velocity No
Scan Modes Gain control in two dimensions for additional level of flexibility for image quality control Yes
Scan Modes Provision for higher resolution Real time high frequency 2D
Scan Modes Probes supplied shall be in latest generation bandwidth Yes
Scan Modes Provision for higher sensitivity for low frequency doppler in all probes Yes
Scan Modes Number of channels in color doppler system 50000 or more (if channels are being designated as digital channels)
Scan Modes Live 3 D imaging in color doppler system No
Scan Modes Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval Yes
Scan Modes Number of grey shades for sharp contrast resolutions in db 256 or more
Scan Modes High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate Yes
Scan Modes Colour Flow Imaging Option Yes
Scan Modes Provision of Tissue Colorization (B-Colour) for improved contrast resolution Yes
Scan Modes All application packages should be inbuilt into the system Yes
Scan Modes Cine Loop Features Yes
Scan Modes Cine Loop Memory in MB >=100
Scan Modes Frame grabber facility for post analysis Yes
Scan Modes User defined system and application presets for multi-user department Yes
Scan Modes Number of transducer/probe ports 3
Scan Modes System should be capable of generating real time live 3- D images No
Scan Modes Contrast agent imaging Yes
Scan Modes Color Doppler system with all applications package, quad loop for serial studies with high frame rate, harmonic imaging capability in all modes and digital storage and retrieval Yes
Image Display and Processing DICOM 3 Compliant Yes
Image Display and Processing Adjustable transmit focus Yes
Image Display and Processing Automated B-mode (2-D) image Yes
Image Display and Processing Automated CDI(Color Doppler Imaging) image optimization Yes
Image Display and Processing Automated PW Doppler image optimization Yes
Image Display and Processing Dynamic receive focus Yes
Image Display and Processing Grayscale levels 256
Image Display and Processing Image magnification (zoom) Yes
Image Display and Processing Real-time image Yes
Image Display and Processing Frozen image Yes
Image Display and Processing Touch Screen No
Image Display and Processing Monitor shall have high-resolution Yes
Image Display and Processing Provision of Tilt or Swivel monitor should be able to view in all angles and all light conditions Yes
Image Display and Processing Type of Display LCD/LED
Image Display and Processing Monitor display size (inch) 21 or more Or higher
Image Display and Processing Split screen Twin View
Image Display and Processing Single/dual monitors Single
Image Display and Processing Depth, cm ≥30
Image Display and Processing Pre processing Yes
Image Display and Processing Post processing Yes
Image Display and Processing Selectable dynamic range (dB) >=200
Image Display and Processing Spectrum analyzer Yes
Image Display and Processing Digital Image Storage Yes
Image Display and Processing Cine loop playback Yes
Image Display and Processing Max number frames >=1000
Image Display and Processing Digital storage hard drive, GB >=500
Image Display and Processing Speckle-tracking strain and strain rate No
Image Display and Processing Exam protocols Yes
Image Display and Processing Digital calipers Yes
Image Display and Processing Exam presets Yes
Image Display and Processing Customizable presets Yes
Image Display and Processing On-screen annotation Yes
Image Display and Processing DVD/CD Writer/ USB No
Image Display and Processing Flash Memory No
Image Display and Processing USB connector Yes
Image Display and Processing Facility for high definition digital acquisition, review and editing of complete patient studies Yes
Image Display and Processing Type of processor (in PC) NA
Image Display and Processing RAM capacity of PC in GB (hint: In case PC not provided put zero) NA
Image Display and Processing Processor speed in GHz (PC) NA
Image Display and Processing Frame Grabber incorporated(PC) No
Image Display and Processing Connectivity between USG and PC No
Image Display and Processing PC with all software inclusive interfaced with USG machine No
Image Display and Processing Laser Color printer provided No
Image Display and Processing Inkjet/Thermal printer provided No
Image Display and Processing CD/DVD/USB Produced should be playable on any system No
Image Display and Processing Glossy Colour Print Paper supplied NA
Image Display and Processing Dicom Interfacability Dicom to PACS Yes
Image Display and Processing Interfacability Dicom to RIS Yes
Image Display and Processing USG sytem supplied should be upgradable to next generation system on site Yes
Power Requirements Power input, VAC 220-240VAC, 50Hz fitted with Indian plug
Power Requirements Resettable over current breaker shall be fitted for protection No
Power Requirements Power backup UPS
Power Requirements Back up time in minutes (minimum) 30.0
Power Requirements Suitable Servo Controlled Stabilizer / CVT should be provided No
Certifications Compliance to Medical Device Rules (MDR) 2017 as amended till date Yes
Certifications Availability of valid drug/Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date Yes
Certifications Certification for manufacturing unit ISO:13485 (Latest)
Certifications Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date Yes
Certifications Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement Yes
Certifications Electrical Safety standards IEC-60601-1-1 or equivalent BIS
Warranty and Maintenance Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 3, 5 Or higher
Miscellaneous Requirements OEM/Reseller shall ensure uninterrupted availability of all spares, consumables and reagents for atleast 10 years Yes
Miscellaneous Requirements Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes
Miscellaneous Requirements User/Technical/Maintenance manuals to be provided in English in hard and soft copy Yes
Miscellaneous Requirements Details of equipments and procedures required for local calibration and routine maintenance to be provided and advanced maintenance task documentation also to be furnished Yes
Miscellaneous Requirements Supplier to perform installation, safety and operation checks before handover Yes
Miscellaneous Requirements Training of users in operation and basic maintenance shall be provided Yes
Miscellaneous Requirements Contact details of manufacturer, supplier and local service agent to be provided Yes
Miscellaneous Requirements Certificate of calibration from the manufacturer Yes