TenderDekho Logo
Active GEM

Government Tender Published for water baths in RAIPUR, CHHATTISGARH

Bid Publish Date

17-Aug-2026, 3:37 pm

Bid End Date

16-Sep-2026, 3:00 pm

Location

RAIPUR , CHHATTISGARH

Progress

Issue17-Aug-2026, 3:37 pm
AwardPending

All India Institute Of Medical Sciences (aiims) invites bids for water baths (Q3) in RAIPUR, CHHATTISGARH. Quantity: 3. Submission Deadline: 16-09-2026 15: 00: 00. Submit your proposal before the deadline.

Tender Data

Bid Details

Quantity

3

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

No

MII Purchase Preference

Yes

MII Preference Band

L1+20%

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

73

OEM Avg. Turnover

3

Past Performance

50 %

Warranty Period

3 years

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

water baths (Q3)

Delivery Details

Max Delivery Days

30

Delivery Locations

1

Delivery Cities

Raipur

Delivery Pincodes

492099

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Mukesh Chaturvedi492099,Tatibandh RaipurRaipurChhattisgarh492099330-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9667095.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Categories 1

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Water Bath Chamber Dimensions, Capacity and Construction Water bath Chamber Capacity >over 14 to 18 litre
Water Bath Chamber Dimensions, Capacity and Construction Chamber Construction: Double walled rectangular chamber
Water Bath Chamber Dimensions, Capacity and Construction Material of Outer Chamber Construction: Epoxy / Powder coated Stainless Steel SS304
Water Bath Chamber Dimensions, Capacity and Construction Number of racks provided with Water bath unit 0
Water Bath Chamber Dimensions, Capacity and Construction Number of 75 mm diameter Holes provided: 12
Heating Arrangement Parameters Heating Capacity (>=): 1000.0
Control Panel and Display Unit Control Panel has: ON/Off Switch, Heating & Temprature (Set & Actual) Indicators, Power mains Indicator, Temperature controller, Circulation Controller (if Water bath has circulation facility)
Control Panel and Display Unit Adjustable shaking frequency in rpm NA
Control Panel and Display Unit Type of Temperature controller Digital controller cum Indicator PID Based control Or higher
Control Panel and Display Unit Water bath Display type: Digital (numerical/application specific) backlit LCD display
Control Panel and Display Unit Integrated circulation pump for temperature homogeneity Yes, No Or higher
Control Panel and Display Unit Removable bottom plate and shaking inserts Yes, No, N/A for shaking insert if the equipment provided without circulation feature Or higher
Water bath Temperature Temperature range of bath chamber: 5°C above ambient to 90°C
Water bath Temperature Temperature control sensitivity: ±0.5°C or better, ±0.2°C or better, ±0.1°C or better Or higher
Water bath Temperature Least temperature increment Step available 0.1 degree C, 0.01 degree C Or higher
Water bath Temperature Temperature Accuracy: ±0.2°C or better, ±0.1°C or better Or higher
Water bath Temperature Safety Features: Low fluid Alarm, High limit Alarm, Over temperature Alarm & cutoff, Redundant safety thermostat
Power Requirement, Certifications and Warranty Power requirement: 220 V 50 Hz Single Phase AC
Power Requirement, Certifications and Warranty Availability of Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification No
Power Requirement, Certifications and Warranty Equipment has CE certification Yes
Power Requirement, Certifications and Warranty Warranty Period: 3, 5 Or higher
Timer Unit Timer Provided Yes
Timer Unit Timer Setting ( minimum increment step) 0.0 - 1.0 Or lower
Miscellaneous Features Drain plug in Chamber provided No
Miscellaneous Features Data Logging facility through (RS 232/USB/HDMI/Bluetooth etc) to computer available: No
Miscellaneous Features Drain screw for emptying of water bath Yes, No Or higher
Miscellaneous Features Seamless and waterproof keypad Yes, No Or higher