TenderDekho Logo
Active GEM

Bids are Invited For Real Time PCR Machine (V2) in KARAIKAL, PUDUCHERRY

Bid Publish Date

21-Aug-2026, 4:59 pm

Bid End Date

12-Sep-2026, 5:00 pm

EMD

₹90,000

Generate Docs

Progress

Issue21-Aug-2026, 4:59 pm
Corrigendum06-Sep-2026
AwardPending

Public procurement opportunity for Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer) Real Time PCR Machine (V2) (Q2) in KARAIKAL, PUDUCHERRY. Quantity: 1 issued by. Submission Deadline: 12-09-2026 17: 00: 00. View full details and respond.

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

No

Startup Exemption/Relaxation

No

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

9

OEM Avg. Turnover

50

Past Performance

50 %

Warranty Period

7 days

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Real Time PCR Machine (V2) (Q2)

Advisory Bank

State Bank of India

ePBG Percentage

5%

ePBG Duration (Months)

62

Delivery Details

Max Delivery Days

15

Delivery Locations

1

Delivery Cities

Karaikal

Delivery Pincodes

609602

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Radha S609602,WRPQ+3J3, Kamarajar Salai Ext, Karaikal, Puducherry 609602KaraikalPuducherry609602115-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9790896.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Authority & Contact

Organization

Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)

Office Name

Jawaharlal Institute Of Postgraduate Medical Education And Research

Grievance Contact

[email protected]

Corrigendum Updates

1 Update
#1

Update

06-Sep-2026

Extended Deadline

12-Sep-2026, 11:30 am

Opening Date

13-Sep-2026, 11:30 am

Categories 2

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERAL INFORMATION Product Name Real Time PCR Machine
PRODUCT INFORMATION System Type Open
PRODUCT INFORMATION Capacity of Blocks 96 well
PRODUCT INFORMATION Number of channels (minimum) 6
PRODUCT INFORMATION Maximum Heating ramp rate in degree per second 5
PRODUCT INFORMATION Maximum Cooling ramp rate in degree per second 5
PRODUCT INFORMATION Adjustable heating / cooling ramp rate Yes Or higher
PRODUCT INFORMATION Operating Temperature range (degree celcius) 4 - 105 degree celcius
PRODUCT INFORMATION Hot Lid Temperature (degree celcius) 30 to 110 degree celcius
PRODUCT INFORMATION Sample volume range in micro litre 5 to 100 ml
PRODUCT INFORMATION Programmable Steps and cycles Yes
PRODUCT INFORMATION Number of USB ports 4
PRODUCT INFORMATION Input power supply Single phase (230 V, 50 Hz)
PRODUCT INFORMATION Auto restart after power outages Yes
PRODUCT INFORMATION Boot up time ≤1 minute
PRODUCT INFORMATION Type of chemistries that can be run on system Taqman, SYBR green, Molecular Beacon and all other fluorescent dye based
PRODUCT INFORMATION Compatibility for well strips 96
PRODUCT INFORMATION Compatibility for Individual PCR tubes 0.1 to 0.2 ml tubes
PRODUCT INFORMATION Source of Excitation Tungsten / Xenon / LED / Halogen
PRODUCT INFORMATION Pre calibration with at least 7 commonly used dyes FAM / SYBR Green / VIC / HEX / NED / TAMRA / ROX / Texas Red / JOE / Cy5 / Quasar 670 / Cy5.5 / Quasar 705 / Cy3
PRODUCT INFORMATION Addition of new dyes should be possible without hardware change Yes
PRODUCT INFORMATION Analysis performed Gene Expression, Plus/minus assay, SNP, Allelic Discrimination and Dissociation Curve Analysis, DNA Quantitation, Gene Expression Analysis, Comparative Analysis Curve, Standard Curve/ Relative Standard Curve
PRODUCT INFORMATION Instrument software should not restrict number of assay or target that can be run on a single 96 well plate in parallel Yes
PRODUCT INFORMATION Suitable software for Data Acquisition, analysis of run and also for Gene Expression analysis by relative quantity or normalized expression Yes
PRODUCT INFORMATION Software should have the capacity to analyze data of minimum 10 different runs at a time Yes
PRODUCT INFORMATION The instrument software must be capable of detecting and analyzing a different gene, SNP or pathogen target in every well of the 96-well plate Yes
PRODUCT INFORMATION Temperature setting accuracy (degree celcius) ± 0.2
PRODUCT INFORMATION Well to well temperature uniformity (degree celcius) ± 0.3
DATA MANAGEMENT SYSTEM Computer system with latest licensed operating system and antivirus provided Yes
DATA MANAGEMENT SYSTEM PC monitor type LCD / LED
DATA MANAGEMENT SYSTEM Minimum PC monitor size (inches) 15 Inches or more
DATA MANAGEMENT SYSTEM PC hard disk 500 GB, 1 TB Or higher
CERTIFICATIONS Compliance to Medical Device Rules (MDR) 2017 as amended till date Yes
CERTIFICATIONS Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date Yes
CERTIFICATIONS Certification for manufacturing unit ISO:13485 (Latest)
CERTIFICATIONS Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date Yes
CERTIFICATIONS Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement Yes
CERTIFICATIONS Electrical Safety Compliance Standard IEC 60601 or Equivalent BIS
WARRANTY Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 5 Or higher